Full metadata record
DC FieldValueLanguage
dc.contributor.authorSai, Cong Doanh-
dc.contributor.authorLuu, Manh Quynh-
dc.date.accessioned2017-08-09T02:18:16Z-
dc.date.available2017-08-09T02:18:16Z-
dc.date.issued2015-
dc.identifier.citationSài, C. D., Luu, M. Q. (2015). High Sensitive Enzyme Based Glucose Sensor Using Lead Sulfide Nanocrystals. VNU Journal of Science: Mathematics – Physic, 31(2), 61-67-
dc.identifier.issn2588-1124-
dc.identifier.urihttp://repository.vnu.edu.vn/handle/VNU_123/55919-
dc.descriptionp. 61-67en_US
dc.description.abstractIn recent years, glucose oxidase (GOx) based sugar level detecting techniques have been intensively developed. In order to improve the diagnosis and desease treatment in low- and middle-income countries, the low cost, easily processing, but still high sensitive sensing systems/equipments play a very important rules in biomedicine and life science. In this work, lead sulfide (PbS) nanocolloids were used as electron receptor. The results showed that the sensitivity of the glucose sensor reached 546.2 μA cm-2 mM-1. It is note that, some early works on GOx based glucose sensor only reached sensitivity less than 100 μA cm-2 mM-1.en_US
dc.language.isoenen_US
dc.publisherH. : ĐHQGHNen_US
dc.relation.ispartofseriesVNU Journal of Science: Mathematics – Physic-
dc.subjectLead sulfide nanoparticlesen_US
dc.subjectglucose sensoren_US
dc.subjectglucose oxidaseen_US
dc.titleHigh Sensitive Enzyme Based Glucose Sensor Using Lead Sulfide Nanocrystalsen_US
dc.typeArticleen_US
Appears in Collections:Mathematics and Physics


  • 32.pdf
    • Size : 316,4 kB

    • Format : Adobe PDF

    • View : 
    • Download : 
  • Full metadata record
    DC FieldValueLanguage
    dc.contributor.authorSai, Cong Doanh-
    dc.contributor.authorLuu, Manh Quynh-
    dc.date.accessioned2017-08-09T02:18:16Z-
    dc.date.available2017-08-09T02:18:16Z-
    dc.date.issued2015-
    dc.identifier.citationSài, C. D., Luu, M. Q. (2015). High Sensitive Enzyme Based Glucose Sensor Using Lead Sulfide Nanocrystals. VNU Journal of Science: Mathematics – Physic, 31(2), 61-67-
    dc.identifier.issn2588-1124-
    dc.identifier.urihttp://repository.vnu.edu.vn/handle/VNU_123/55919-
    dc.descriptionp. 61-67en_US
    dc.description.abstractIn recent years, glucose oxidase (GOx) based sugar level detecting techniques have been intensively developed. In order to improve the diagnosis and desease treatment in low- and middle-income countries, the low cost, easily processing, but still high sensitive sensing systems/equipments play a very important rules in biomedicine and life science. In this work, lead sulfide (PbS) nanocolloids were used as electron receptor. The results showed that the sensitivity of the glucose sensor reached 546.2 μA cm-2 mM-1. It is note that, some early works on GOx based glucose sensor only reached sensitivity less than 100 μA cm-2 mM-1.en_US
    dc.language.isoenen_US
    dc.publisherH. : ĐHQGHNen_US
    dc.relation.ispartofseriesVNU Journal of Science: Mathematics – Physic-
    dc.subjectLead sulfide nanoparticlesen_US
    dc.subjectglucose sensoren_US
    dc.subjectglucose oxidaseen_US
    dc.titleHigh Sensitive Enzyme Based Glucose Sensor Using Lead Sulfide Nanocrystalsen_US
    dc.typeArticleen_US
    Appears in Collections:Mathematics and Physics


  • 32.pdf
    • Size : 316,4 kB

    • Format : Adobe PDF

    • View : 
    • Download :